Robotic surgery is minimally invasive surgery. SASES and the Hernia Interest Group formally support the robotic platform as an evolution of laparoscopic care — not a separate experimental category — and have set the standards under which South African surgeons adopt it: the 2024 minimum-standard guidance for robotic colorectal surgery (with the South African Colorectal Society) and three position statements of November 2025 on patient access, advanced colorectal adenomas and robotic hernia repair. This page explains how accreditation works and summarises the statements; members can download the full documents from the robotic surgery folder of the library.
Why the platform matters
Conventional laparoscopy remains an excellent approach. The robotic platform adds stable three-dimensional vision without physiological tremor, articulated instruments that reach the deep pelvis and complex abdominal-wall planes, and ergonomics that keep a surgeon fresh through long procedures. In rectal surgery its best-documented benefit is a lower conversion rate — and conversion to open surgery means more complications, higher episode cost and delayed chemotherapy, with poorer five-year disease-free survival. In hernia surgery it offers a minimally invasive option for large or complex defects that would otherwise be repaired open: in the 2023 meta-analysis of 58 studies, robotic inguinal repair had lower recurrence than laparo-endoscopic repair, and robotic ventral repair had fewer bowel injuries and conversions than laparoscopy and, against open repair, fewer complications and surgical-site infections and a stay 3.4 days shorter.
The trial data, the costs and the funding argument are set out in full in Robotic surgery: the evidence and the economics.
How accreditation works: two processes, one file
Robotic accreditation in South Africa is a joint product of the platform provider's training pathway and the Society's standards. The provider (Intuitive for the da Vinci system; Medtronic's Hugo and CMR's Versius run equivalent programmes) certifies that a surgeon and their team can use the technology safely; SASES, with the South African Colorectal Society and HIGSA, sets who may enter that pathway, what must be documented, and how practice is maintained and peer-reviewed. Hospital groups and funders look for both. The pattern is the same as the SAGES/ACS and European consensus model: a structured programme before privileges, proctored early cases, and ongoing volume and outcome review by the surgeon's own society and hospital.
1. The platform pathway
| Application | The surgeon applies to the robot's owner (the hospital's robotic programme or steering committee) and the platform provider, with evidence of minimally invasive proficiency and intended procedure track. The hospital's credentialing process runs alongside. |
|---|---|
| Technology training | Online modules with assessment, an in-service on the system, and a simulator curriculum on the console — a required set of exercises and hours with pass scores that must be met before in-person training. Case observation at an established centre is part of this phase. |
| In-platform training | A one- to two-day hands-on course at a provider-accredited training centre — dry-lab and, for most tracks, wet-lab or cadaveric procedure training — attended by the surgeon and their bedside assistant; the theatre team (robot-trained scrub sister and assistant) is trained in parallel. |
| Proctored case series | The surgeon's first cases are performed in their own theatre, on their own system, under observation by a recognised proctor in the same track. In principle nine cases within ninety days of the platform training, the first with provider case support; the proctor may lengthen the series. Independent practice follows the proctor's sign-off. |
| Continuing development | Ongoing simulator work, procedure video review, advanced courses and congress sessions; the provider's case data and the Society's database feed the annual review. |
2. Tracks
Training and proctoring are procedure-track specific. In South Africa the two common tracks are colorectal (pelvic and colonic resection) and abdominal wall and hernia (inguinal, ventral and incisional repair, including retro-muscular mesh placement); upper GI, bariatric and HPB tracks follow the same structure. A surgeon accredited in one track adds another through that track's procedure-specific training, observation and proctored cases — not by extension of the first.
3. The Society's standards (2024 guidance, colorectal track)
| Entry | Proficiency in minimally invasive pelvic dissection with outcomes in keeping with international standards. Until robust outcomes data exist, volume is the measure: at least 15 minimally invasive pelvic dissections a year (TME or partial mesorectal excision, anterior resection, abdominoperineal resection, ventral mesh rectopexy, proctectomy with or without pouch), sustained over three years. Only surgeons who can show outcomes or volume enter the platform pathway. |
|---|---|
| Maintaining accreditation | Without outcomes data, at least 10 robotic procedures a year as primary surgeon, or 15 as primary or assistant; every case entered, with outcomes, in a Society-accredited robotic or ERAS database (POPIA-compliant, for research). |
| System and theatre | A fully operational robot with its connectivity in place and all anticipated and emergency consumables on site; no robotic surgery if the theatre UPS is faulty; a full team including a robot-trained scrub sister (who prepares, docks and undocks but does not assist) and a robot-trained surgical assistant. |
| Non-compliance and peer review | A surgeon who falls below these standards loses accreditation and must repeat all or part of the proctorship. Peer review sits with the South African Colorectal Society, with ASSA and SASES as needed; queries from hospitals, surgeons or funders come to SASES. |
For the hernia track HIGSA applies the same structure — unit readiness, trained team, proctored start, every case in the HIGSA registry — under its 2025 position statement below.
Advanced colorectal adenomas (SASES guideline, November 2025)
Endoscopic resection is first-line for large non-pedunculated polyps with no suspicion of malignancy; piecemeal removal is avoided where malignancy is suspected. The surgeon to whom the patient is referred should perform their own endoscopy, with enhanced-imaging photo-documentation, to judge resectability. Surgical resection, following oncological principles with full lymphadenectomy, is indicated for polyps larger than 4 cm, any suspicion of malignancy (pit pattern type 3, Paris 0-IIc or 0-IIa+IIc morphology, non-lifting, high-grade dysplasia in a large adenoma), and polyps over 2 cm at high risk of incomplete resection or recurrence — those involving the ileocaecal valve, appendix, a diverticulum or the dentate line, within a segment of colitis, after a failed or recurrent resection, non-lifting after adequate submucosal injection, or in a position the endoscopist judges difficult. Where surgery is indicated, the robotic platform follows the same principles, in suitable patients, by trained and accredited robotic colorectal surgeons.
Robotic-assisted hernia repair (HIGSA position statement, November 2025)
- Robotic hernia surgery should only be performed in units with an adequately trained surgeon and nursing staff and with institutional support.
- It may be considered in all hernia repair — training programmes should begin with simple cases — and should be specifically considered in complex hernias, including cases previously planned for open repair.
- All robotic hernia repairs should be entered in the HIGSA registry so that South African outcomes are monitored and research generated.
Patient access and funding (SASES position statement, November 2025)
Minimally invasive colorectal surgery is the standard of care; the robotic platform is one of its approaches, used in South Africa only by experienced, high-volume surgeons under the standards above. SASES's position is that every patient with colorectal pathology who is a candidate for the proven indications of robotic surgery should have access to the platform, and that funders may not decline funding for robotic colorectal surgery where the patient or another party covers the additional cost over and above the funder's standard principles. Members who meet a blanket refusal should cite the position statement in the motivation and inform the Society.
What this means in practice
- Planning to start? Check the entry volume first, then apply to your hospital's robotic programme and the provider together, and book the simulator time early — it is the step that most often delays the course date. Bring your assistant.
- Just trained? Line up the nine proctored cases before the course so they fall inside the ninety days; agree the proctor and provider case support in advance.
- Already operating robotically? Keep the volume thresholds in view, log every case with outcomes, enter hernia repairs in the HIGSA registry, and keep the accreditation file — training certificates, proctor sign-off, case log — current; it is what hospital groups and funders will ask for.
- Adding a track? Expect procedure-specific modules, observation and a fresh proctored series for the new track.
Questions about accreditation, proctors or a funder dispute: